Put power on a pitched roof without a second layer of rails and modules. We supply crystalline solar roof tiles to roofing contractors, developers and distributors. Tiles are manufactured to your drawing by partner production lines; we handle specification, samples, pre-shipment checks and export.
Solar roof tiles are roofing units with photovoltaic cells laminated into the tile itself, so one product both sheds water and generates electricity. The crystalline tiles we supply come in two formats, 650 × 432 mm at 43 W and 1208 × 432 mm at 85 W, with 3.2 mm + 3.2 mm double glass and 182 mm monocrystalline cells (supplier datasheet).
- Two formats, one system: 43 W (650 × 432 × 22 mm, 5.5 kg) and 85 W (1208 × 432 × 22 mm, 10 kg), both rated for a 1000 V system.
- Built like a roof, not a panel: 3.2 mm + 3.2 mm double glass, IP67 junction box, 182 mm monocrystalline cells.
- Colour-matched: terracotta, grey and black finishes as standard references; other colours quoted on request.
Solar roof tiles, solar shingles, BIPV roof tiles: one product family, several names. Solar roof tiles (also called solar shingles, BIPV roof tiles or photovoltaic roof tiles) are building-integrated photovoltaic (BIPV) products that replace part of the roof covering. They are not rack-mounted solar panels, which sit on hooks and rails above an existing roof.
On this page, "solar roof tile" means the crystalline glass-glass tile described in the specification table.
Who solar roof tiles suit
Why solar roof tile projects stall before the first tile ships
Solar roof tile projects usually stall in procurement, not on the roof. The product is new to most buying teams, so the same four or five questions come up on every job, and each one can hold a project for weeks.
The design committee rejects the panels. Heritage districts, homeowner associations and developer design codes often refuse rack-mounted modules on street-facing roofs. If the only solar option is a panel on rails, the solar line gets cut from the project.
Low-pitch roofs raise waterproofing doubts. A tile that also carries cells and cables has to shed water as well as a plain tile does. On shallow pitches, the roofer carries that risk, and roofers do not sign off on overlap details they have not seen.
The colour does not match the rest of the roof. A solar section that reads as a black rectangle on a terracotta roof defeats the reason for choosing tiles in the first place. Matching has to be settled before production, not discovered on delivery.
Warranty claims bounce between suppliers. When the tiles, the flashing and the electrical parts come from different vendors, a leak or a failed string turns into a question of whose fault it is. Buyers want one party accountable for the tile as both roofing and generator.
Samples take too long to decide on. Architects want a physical tile on the table for colour and fit. A slow or unclear sample process pushes the decision past the tender date.
Solar roof tile specifications: two crystalline formats
Solar roof tiles in this line share one construction and differ only in length: the 650 mm tile delivers 43 W and the 1208 mm tile delivers 85 W. All figures below are taken from the supplier datasheet at standard test conditions.
| Parameter | 43 W tile | 85 W tile |
|---|---|---|
| Size (L × W × H) | 650 × 432 × 22 mm | 1208 × 432 × 22 mm |
| Maximum power (Pmax) | 43 W | 85 W |
| Open-circuit voltage (Voc) | 8.2 V | 16.4 V |
| Short-circuit current (Isc) | 6.32 A | 6.32 A |
| Voltage at max power (Vmp) | 7.0 V | 14.0 V |
| Current at max power (Imp) | 6.08 A | 6.08 A |
| Weight | 5.5 kg | 10 kg |
| Glass | 3.2 mm + 3.2 mm double glass | |
| Cells | 182 mm monocrystalline | |
| Encapsulant | PVB, POE or EVA (chosen per order) | |
| Junction box | IP67 | |
| Connector | MC4, 45 cm leads | |
| NOCT | 45 °C | |
| Temperature coefficient of Pmax | −0.38 %/°C | |
| Temperature coefficient of Voc | −0.36 %/°C | |
| Temperature coefficient of Isc | +0.07 %/°C | |
| Maximum system voltage | 1000 V | |
| Maximum series fuse rating | 15 A | |
| Annual degradation | ≤ 0.5 % per year (supplier stated) | |
| Power density | ~170 W/m² (supplier stated) | |
| Packing | Wooden crate; quantity per crate confirmed with the quote | |
The two formats share the same current (6.08 A at max power), so check how to mix them in your string design. The shorter 43 W tile covers the spots where a full-length tile will not fit, such as edges and dormers.
How solar roof tiles install
Each tile uses a low-pitch waterproof overlap design (supplier stated), with an edge rail that locks into the neighbouring tile. Minimum roof pitch, batten spacing and fixing method are confirmed per project against your roof build-up, rather than assumed from a brochure.
For roofs where a tile system is the wrong fit, such as membrane flat roofs, the comparison in our flat roof solar mounting guide covers the ballasted and fixed options.
What can be customised
- Size: length and width outside the two standard formats, for non-standard tile profiles.
- Thickness: glass build-up quoted per project.
- Colour: terracotta, grey and black seen in production; other colours on request. Send a physical sample of your roof and confirm the match on a paid sample.
- Encapsulant: PVB, POE or EVA, chosen per order.
- Junction box and lead length: the standard lead is 45 cm with MC4 connectors; other lengths on request.
Custom colour, size and encapsulant requests follow the same drawing-to-sample route as our custom solar panels: send the drawing and target output, get a sample quote back.
Send your roof drawing for a quote
Test documents and installation examples for solar roof tiles
Project specifications often call for IEC 61215 and IEC 61730 reports. Tell us which documents your project needs and we confirm what is available with the quote.
Solar roof tiles vs roof tiles plus rack-mounted panels: where the cost goes
Solar roof tiles replace two purchases, the roof covering and the solar array, with one. Whether that is cheaper depends on the roof, so the useful comparison is line by line rather than a single price per watt.
| Cost line | BIPV solar tile roof | Conventional tiles + rack-mounted modules | Direction for tiles |
|---|---|---|---|
| Roofing material on the solar area | Solar tiles are the roof covering | Full tile roof, then modules on top | ▼ one material instead of two [project-specific] |
| Mounting rails and hooks | Tile edge rails and battens | Roof hooks, rails and clamps (see brackets for rack-mounted arrays) | ▼ no separate racking |
| Roof penetrations | None added for racking | One per hook, each to be flashed | ▼ fewer leak points |
| Output per m² | ~170 W/m² (supplier stated) | Check the module datasheet | = / ▼ compare both datasheets |
| Aesthetics and planning approval | Reads as a tile roof | Visible array on the roof plane | ▲ easier where codes restrict panels |
| Replacing one failed unit | Swap one tile (43 W or 85 W) | Swap one module, usually a larger unit | ▲ smaller unit to replace |
| Number of electrical connections | More, smaller units per kW | Fewer, larger units per kW | ▼ more connectors to install and check |
Line for your internal memo: "Solar roof tiles remove the racking, hooks and roof penetrations of a rack-mounted array and replace part of the tile order, so compare installed cost per m² of finished, generating roof, not module price per watt."
For re-roofs and new builds, the saved roofing material and racking is real money. For a sound existing roof with years of life left, rack-mounted modules usually cost less per watt, and our guide to choosing a solar mounting system is the better starting point.
Samples, test data and warranty for solar roof tile orders
Solar roof tile orders start with paper and a physical sample, so the risk of a wrong colour or a wrong spec is caught before production. Here is what is available today and what is still being set.
| Item | Status |
|---|---|
| Model-specific test reports | Confirmed in the project quote |
| Samples | Paid samples, quoted on request |
| Product and power warranty | Stated in the project quote |
| Minimum order quantity | Confirmed in the project quote |
| Production lead time | Confirmed in the project quote |
How to spec a solar tile roof in 5 steps
- Measure the solar area. Send the roof plan with pitch, orientation and the tile profile you are matching.
- Pick the format mix. Use 85 W tiles for the main field and 43 W tiles for edges, hips and dormers.
- Fix the finish. Choose terracotta, grey, black or a matched colour, and the encapsulant (PVB, POE or EVA).
- Size the strings. Set string length against your inverter input window, the 1000 V system limit and the 15 A series fuse rating.
- Approve a paid sample. Check colour, fit and the overlap detail on a physical tile before the production order.
Our team works the same way on every custom project; the guide to choosing a custom solar panel manufacturer lists the questions we expect you to ask us.
Solar roof tiles: questions buyers ask
Are solar roof tiles worth it?
Solar roof tiles are worth it when the roof is being built or replaced anyway, or when planning rules block visible panels. On a sound existing roof with no aesthetic restriction, rack-mounted modules usually deliver more watts per dollar.
What are the disadvantages of solar roof tiles?
The main disadvantages of solar roof tiles are more electrical connections per kilowatt and output per m² that must be checked against a standard module datasheet. An 85 W tile means roughly 12 tiles per kilowatt, each with its own MC4 pair, so installation time on the electrical side goes up.
How much does a solar tile roof cost?
The cost of a solar tile roof depends on roof area, tile format mix, colour and order volume, so it is quoted per project. Send the roof plan through the project quote form and the quote comes back itemised by format.
Are solar tiles as good as solar panels?
Solar tiles use 182 mm monocrystalline cells, a cell size also common in standard panels, but they are built as a roofing product first. Per m², a rack-mounted panel may produce more; per finished roof, tiles remove the racking and the second layer. Compare the two datasheets side by side for your roof.
Can the colour be matched to an existing roof?
Send a physical sample of your roof for a colour match check. Terracotta, grey and black are the standard references; other colours are quoted on request and confirmed on a paid sample before production.
Do solar roof tiles replace the roof covering?
Solar roof tiles replace the roof covering on the area they occupy, so no separate tile sits underneath them. The rest of the roof uses conventional tiles; confirm the profile and colour match for each project.
How are solar roof tiles wired?
Solar roof tiles are wired in series strings through MC4 connectors on 45 cm leads, like conventional modules. Each string stays within the 1000 V maximum system voltage and the 15 A maximum series fuse rating from the datasheet. Guidance on system sizing from the U.S. Department of Energy homeowner's guide applies to tile systems as well.
What is the minimum order?
The minimum order for solar roof tiles is confirmed in the project quote. Samples are paid and quoted on request.
Send the roof plan, the tile profile you are matching and the target output. If a tile roof is the wrong answer for that building, we will tell you and point you to the rack-mounted option.